Dell POWEREDGE C6105 User Manual
Page 20
20
Table 1-4. Table Temperature Thresholds (
continued
)
Temperature
Sensor Number
UNCT
UCT
P1_DIMM_TEMP
0x4D
96
98
Chassis_Ambient
0x54
48
50
Outlet_TEMP
0x42
N/A
N/A
Table 1-9. Voltage Thresholds
Voltage Sensor
Sensor
Number
Normal
LCT
LNCT
UNCT
UCT
CPU_0_Vcore
0x10
1.00V
N/A
N/A
N/A
N/A
CPU_1_Vcore
0x11
1.00V
N/A
N/A
N/A
N/A
DDRP0_Voltage
0x12
1.5V
1.349V
1.388V
1.599V
1.646V
DDRP1_Voltage
0x13
1.5V
1.349V
1.388V
1.599V
1.646V
DDRP0_Voltage (LV)
0x12
1.35V
1.209V
1.248V
1.443V
1.482V
DDRP1_Voltage (LV)
0x13
1.35V
1.209V
1.248V
1.443V
1.482V
P5V
0x28
5V
4.472V
4.628V
5.330V
5.486V
P3V3
0x15
3.3V
2.958V
3.062V
3.526V
3.629V
Table 1-10. Current Thresholds
Current Sensor
Sensor
Number
LCT LNCT UNCT UCT
MB_12V_Current
0xCA
N/A
N/A
N/A
N/A
PSU1_OUT_Current
0x70 N/A
N/A
N/A
N/A
PSU2_OUT_Current
0x71 N/A
N/A
N/A
N/A
Table 1-11. Fan Thresholds
Fan Sensor
Sensor Number
LCT
LNCT
UNCT
UCT
FCB Fan 1
0x6B
1000
1200
N/A
N/A
FCB Fan 2
0x6C
1000
1200
N/A
N/A
FCB Fan 3
0x6D
1000
1200
N/A
N/A
FCB Fan 4
0x6E
1000
1200
N/A