Table 1-4. Table Temperature Thresholds (

continued

)

Temperature

Sensor Number

UNCT

UCT

P1_DIMM_TEMP

0x4D

96

98

Chassis_Ambient

0x54

48

50

Outlet_TEMP

0x42

N/A

N/A

Table 1-9. Voltage Thresholds

Voltage Sensor

Sensor

Number

Normal

LCT

LNCT

UNCT

UCT

CPU_0_Vcore

0x10

1.00V

N/A

N/A

N/A

N/A

CPU_1_Vcore

0x11

1.00V

N/A

N/A

N/A

N/A

DDRP0_Voltage

0x12

1.5V

1.349V

1.388V

1.599V

1.646V

DDRP1_Voltage

0x13

1.5V

1.349V

1.388V

1.599V

1.646V

DDRP0_Voltage (LV)

0x12

1.35V

1.209V

1.248V

1.443V

1.482V

DDRP1_Voltage (LV)

0x13

1.35V

1.209V

1.248V

1.443V

1.482V

P5V

0x28

5V

4.472V

4.628V

5.330V

5.486V

P3V3

0x15

3.3V

2.958V

3.062V

3.526V

3.629V

Table 1-10. Current Thresholds

Current Sensor

Sensor

Number

LCT LNCT UNCT UCT

MB_12V_Current

0xCA

N/A

N/A

N/A

N/A

PSU1_OUT_Current

0x70 N/A

N/A

N/A

N/A

PSU2_OUT_Current

0x71 N/A

N/A

N/A

N/A

Table 1-11. Fan Thresholds

Fan Sensor

Sensor Number

LCT

LNCT

UNCT

UCT

FCB Fan 1

0x6B

1000

1200

N/A

N/A

FCB Fan 2

0x6C

1000

1200

N/A

N/A

FCB Fan 3

0x6D

1000

1200

N/A

N/A

FCB Fan 4

0x6E

1000

1200

N/A

N/A