Dcmi v1.0 – Dell POWEREDGE C6105 User Manual

Page 66

Advertising
background image

66

DCMI V1.0

The following table lists the command support list.

VLAN Configuration

The VLAN is confiugred through the IPMI Set/Get LAN Configuration

command.
To configure the VLAN:

4 Get VLAN ID :

>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C

0x02 0x01 0x14 0x00 0x00
>11 00 00

VLAN is disabled/VLAN ID is zero.

5 Enable and Set VLAN ID :

>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C

0x01 0x01 0x14 0x02 0x80

6 Disable VLAN ID :

>ipmitool -H <BMC IP Address> -I lanplus -U root -P root raw 0x0C

0x01 0x01 0x14 0x00 0x00

BMC Version Information

The BMC firmware version can be obtained by using the IPMI - Get Device

ID command.
To get the BMC firmware version:

Table 1-47. DCMI Commands

Command

NetFn

CMD

O/M

Supported

Get DCMI Capability Info

DCGRP (2Ch)

01h

M

Yes

Get Asset Tag

DCGRP (2Ch)

06h

M

Yes

Get DCMI Sensor Info

DCGRP (2Ch)

07h

M

Yes

Get Power Reading

DCGRP (2Ch)

02h

O

Yes

Get Power Limit

DCGRP (2Ch)

03H

O

Yes

Set Power Limit

DCGRP (2Ch)

04h

O

Yes

Activate/Deactivate Power Limit

DCGRP (2Ch)

05h

O

Yes