Invalid CPU speed detected

Microprocessor not supported by
system

Install a correct version of the microprocessor in the specified
microprocessor connector. See "

Adding or Replacing a

Microprocessor

" in "Installing System Board Options." 

Invalid NVRAM configuration,
resource reallocated

System detected and corrected a
resource conflict when system
resources were allocated using the
System Setup program.

No action is required.

I/O parity interrupt at address

Expansion card improperly installed or
faulty

Reinstall the expansion cards. See "

Installing an Expansion Card

" in

"Installing System Board Options." If the problem persists, replace
the expansion card. See "

Removing an Expansion Card

" in

"Installing System Board Options."

Keyboard failure

Keyboard data line failure

Keyboard stuck key failure

Keyboard clock line failure

Keyboard cable connector loose or
improperly connected, defective
keyboard, or defective
keyboard/mouse controller (defective
system board)

Check the keyboard cable connection. Replace the keyboard. If the
problem persists, replace the system board. See "

Getting Help

," for

instructions on obtaining technical assistance.

Keyboard controller failure

Defective keyboard/mouse controller
(defective system board)

Replace the system board. See "

Getting Help

," for instructions on

obtaining technical assistance.

Memory address line failure at
address, read value expecting

value

Memory data line failure at
address, read value expecting
value

Memory double word logic failure
at address, read value expecting

value

Memory odd/even logic failure at
address, read value expecting

value

Memory write/read failure at
address, read value expecting

value

Faulty or improperly seated memory
modules or defective system board 

Remove and reseat the memory modules. See "

Installing Memory

Modules

" in "Installing System Board Options." If the problem

persists, replace the memory modules. See "

Installing Memory

Modules

" in "Installing System Board Options." If the problem still

persists, see "

Getting Help

," for instructions on obtaining technical

assistance.

Memory allocation error

Faulty application

Restart the application.

Memory parity interrupt at
address

Improperly seated or faulty memory
modules 

Remove and reseat the memory modules. See "

Installing Memory

Modules

" in "Installing System Board Options." If the problem

persists, replace the memory modules. See "

Installing Memory

Modules

" in "Installing System Board Options." If the problem still

persists, see "

Getting Help

," for instructions on obtaining technical

assistance.

Memory tests terminated by
keystroke

POST memory test terminated by
pressing the spacebar

No action is required.

No boot device available

Faulty diskette, diskette/CD-ROM
subsystem, hard-disk drive, hard-disk
drive subsystem, or no boot disk in
drive A

Replace the diskette or hard-disk drive. See "

Installing Drives

." If

the problem persists, replace the system board. See "

Getting Help

,"

for instructions on obtaining technical assistance.

No boot sector on hard-disk
drive

Incorrect configuration settings in
System Setup program, or no
operating system on hard-disk drive

Check the hard-disk drive configuration settings in the System
Setup program. See "Using the System Setup Program," in the
User's Guide
 for instructions. 

No timer tick interrupt

Defective system board

Replace the system board. See, "

Getting Help

," for instructions on

obtaining technical assistance.

Non-system disk or disk error

Faulty diskette, diskette/CD-ROM
subsystem, or hard-disk drive
subsystem

Replace the diskette or hard-disk drive. See "

Installing Drives

." If

the problem persists, replace the system board. See "

Getting Help

,"

for instructions on obtaining technical assistance.

Not a boot diskette

No operating system on diskette

Use a bootable diskette.

Processor in socket 1 not
installed!

No microprocessor installed in primary
microprocessor socket

Install a VRM or a microprocessor in the primary microprocessor
socket. See "

Microprocessor Upgrades

" in "Installing System

Board Options."

Read fault

Requested sector not found

Faulty diskette, diskette/CD-ROM
subsystem, or hard-disk drive
subsystem (defective system board)

Replace the diskette or hard-disk drive. See "

Installing Drives

." If

the problem persists, replace the system board. See "

Getting Help

,"

for instructions on obtaining technical assistance.