Troubleshooting the System Battery

Problem

l

Error message shows problem with the battery

l

System setup program loses the system configuration information

l

System date and time will not stay current

Action

1.  Check the connection of the coin cell battery to the system board.

See "

Replacing the System Battery

" in "Installing System Board Options."

2.  If the problem is not resolved by reseating the battery, replace the battery.

If the problem is not resolved by replacing the battery, see "

Getting Help

," for instructions on obtaining technical assistance.

Troubleshooting Redundant Power Supplies

Problem

l

Amber fault indicator on the system front panel lights up

l

Red fault indicator blinks on the power supply or is lit up continuously

Action

1.  Open the front bezel.

See "

Removing the Front Bezel

."

2.  While grasping the power supply handle, push down on the release lever and pull the power supply straight out to clear the chassis.

3.  Slide the new power supply into the chassis.

Troubleshooting a Cooling Fan

Problem

l

Amber fault indicator on the system front bezel lights up

l

Server management application program issues a fan-related error message

Action

1.  Open the front bezel.

See "

Removing the Front Bezel

."

2.  Remove the system cover.

3.  Locate the faulty fan and while pressing the release lever, grasp the fan and lift straight up to clear the fan assembly (see

Figure 5-6

).

WARNING:

There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type

recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions.

CAUTION:

The power supplies are hot-pluggable. The system requires two power supplies to be installed for the system to operate normally.

The system is in the redundant mode when all three power supplies are installed. Remove and replace only one power supply at a time.

NOTE:

There are two fan assemblies containing two individual fans. One assembly is located near the SCSI backplane board. The other fan assembly is

attached to the back-panel.

CAUTION:

The cooling fans are hot-pluggable. To maintain proper cooling while the system is on, only replace one fan at a time.