Hot swap, Initialization, Int 13h – Dell PowerEdge RAID Controller S100 User Manual

Page 106: Jbod (just a bunch of disks [drives]), Led (light emitting diode), Load balancing, Mirroring, Nas (network attached storage)

Advertising
background image

106

Glossary

H

O T

S

W A P

Replacement of a failed component while the system is running and

operating normally.
I

N I T I A L I Z A T I O N

The process of writing zeros to the data fields of a virtual disk

and, in fault tolerant RAID levels, generating the corresponding parity to put the

virtual disk in a Ready state. Initialization generates parity information, so that the

virtual disk is redundant. Virtual disks can work without initialization, but they are not

truly redundant until initialization is performed.
INT 13

H

A DOS interrupt used to activate seek, read, write and format disk

functions. The Int 13h interface supports physical disks that contain up to an

approximate maximum disk space of 8.45 GB.
JBOD (J

U S T

A

B

U N C H

O F

D

I SK S

[D

RI VE S

]) — A storage subsystem that uses a

single or multiple, independent disk drives.
LED (L

I G H T

E

MI T T I N G

D

I O D E

) — An electronic device that illuminates when

powered.
L

O A D

B

A L A N C I N G

Load balancing is a method of spreading work between two or

more computers, network links, CPUs, physical disk drives, or other resources. Load

balancing is used to maximize resource use, throughput, or response time. In the

controllers, the balancing service is performed by the firmware. You can choose

between a single path for load balancing, and a “round-robin” load balancing scheme.

In single path, the firmware can detect multiple paths to a device, and use only a single

path for I/O activity to that device. The secondary path is used if a failure is detected

on the primary path. If load balancing is enabled for the controller, the firmware

implements a round-robin scheme to issue I/Os to the redundant path device. The

round-robin scheme issues one I/O down one path, and the other I/O down the second

path, and so on. There is no restriction on firmware regarding which path to choose

first. If load balancing is disabled, the firmware can use any one of the available paths

to issue I/Os, and it should continue to use the same path for all further I/O activity.

On reboot or path failure, the firmware again chooses any available path.
MB — Acronym for megabyte(s). The term megabyte means 1,048,576 bytes (2^20

bytes); however, when referring to hard drive storage, the term is often rounded to

mean 1,000,000 bytes.

M I RR O R I N G

The process of providing complete redundancy using two physical

disks, by maintaining an exact copy of one physical disk’s data on the second physical

disk. If one physical disk fails, the contents of the other physical disk can be used to

maintain the integrity of the system and to rebuild the failed physical disk.
NAS (N

E T W O RK

A

T TA CH ED

S

T O R A G E

) — A server that runs an operating system for

handling files, and which is accessible directly on a LAN by using protocols like

TCP/IP.

A5_bk0.book Page 106 Thursday, February 10, 2011 8:34 PM