Troubleshooting, System startup problems, Table 7-1. system does not boot – Dell PowerEdge RAID Controller S100 User Manual

Page 61

Advertising
background image

Troubleshooting

61

7

Troubleshooting

To get help with your Dell PowerEdge RAID Controller (PERC) PERC S100

adapter and PERC S300 adapter, contact your Dell Technical Service

representative or access the Dell Support Web site at support.dell.com.
The chapter discusses four major categories of troubleshooting:

• Normal tasks that cannot be performed during system startup.
• Warning messages that might appea

r at the Dell Inc. PERC S100

Controller BIOS or Dell Inc. PERC S300 Controller BIOS screen.

• Functions that cannot be performed with virtual disks.
• Functions that cannot be performed with physical disks.

NOTE:

Unless mentioned otherwise, the term PERC Virtual Disk Management utility

refers to both the PERC S100 Virtual Disk Management utility and the PERC S300

Virtual Disk Management utility.

System Startup Problems

The following table indicates potential PERC S100 adapter or PERC S300

adapter-related causes for system startup problems.

Table 7-1. System Does Not Boot

Likely Causes to Check

Corrective Actions

Controller mode is set

incorrectly at System Setup

1

At system startup, when the Dell Power-On Self-

Test (POST) screen appears, press <F2> to enter

the

Dell Inc. PowerEdge BIOS screen.

2

Scroll to SATA Settings. Press <Enter> and

make sure that the following is true:
• For a PERC S100 adapter: SATA Controller

is set to a RAID mode.

• For a PERC S300 adapter: SATA Controller

is set to ATA Mode or AHCI.

NOTE:

Data might be lost when switching from

RAID Mode to ATA Mode.

A5_bk0.book Page 61 Thursday, February 10, 2011 8:34 PM