Dell PowerEdge 6600 User Manual

Page 24

Advertising
background image

sets in the following bank(s):

Bank x

Amount of available memory limited to

256 MB!

OS Install Mode is enabled in the
System Setup program.

Disable OS Install Mode in the System Setup program (see "Using the
System Setup program" in the User's Guide).

Auxiliary device failure

Loose or improperly connected mouse
or keyboard cable; faulty mouse or
keyboard; faulty I/O riser card.

See "

Troubleshooting the Mouse

" and "

Troubleshooting the Keyboard

"

in "Troubleshooting Your System."

BIOS Update Attempt Failed!

Remote BIOS update attempt failed.

Retry the BIOS update. If the problem persists, see "

Getting Help

."

Caution! NVRAM_CLR jumper is installed

on system board. Please run SETUP

Incorrect configuration settings in
System Setup program; NVRAM_CLR
jumper is installed; faulty system
battery.

Check the System Setup configuration settings (see "Using the System
Setup Program" in the User's Guide). Remove the NVRAM_CLR jumper
(see

Figure A

-2

for jumper location).

CD-ROM drive not found

Improperly connected or missing CD
drive.

See "

Troubleshooting a CD Drive

" in "Troubleshooting Your System."

Checking embedded server management

firmware

Embedded server management
memory may be temporarily corrupted.

To clear the embedded server management memory, shut down the
system, disconnect the power cords, wait approximately 30 seconds,
reconnect the power cords, and then restart the system. If the
problem persists, see "

Getting Help

."

CPU population error!

Faulty, improperly installed, or
unsupported microprocessor.

See "

Troubleshooting the Microprocessor Board

" in "Troubleshooting

Your System."

CPU VRM Failure/missing/mismatch

detected

Faulty, unsupported, or missing VRM
(s).

Ensure that supported VRMs of the same type are properly installed. If
the problem persists, replace the VRM (see "

Adding or Replacing a

Microprocessor

" in "Installing System Options").

CPUs with different level-3 cache sizes

detected

Microprocessors with different level 3
(L3) cache sizes are installed.

Ensure that all microprocessors have the same cache size and that
they are properly installed (see "

Adding or Replacing a Microprocessor

"

in "Installing System Options").

Data error

Faulty diskette, diskette drive, or hard
drive.

See "

Troubleshooting the Diskette Drive

," "

Troubleshooting a CD

Drive

," and "

Troubleshooting Hard Drives

" in "Troubleshooting Your

System."

Decreasing available memory

Faulty or improperly installed memory
modules.

See "

Troubleshooting System Memory

" in "Troubleshooting Your

System."

Diskette drive n seek failure

Incorrect configuration settings in
System Setup program.

Run the System Setup program to correct the settings (see "Using the
System Setup Program" in the User's Guide).

Faulty or improperly installed diskette
drive, or loose diskette/CD interface
cable.

See "

Troubleshooting the Diskette Drive

" in "Troubleshooting Your

System."

Diskette read failure

Faulty or improperly inserted diskette. Replace the diskette.

Diskette subsystem reset failed

Faulty diskette/CD drive controller;
faulty peripheral riser card.

See "

Troubleshooting the Diskette Drive

" in "Troubleshooting Your

System."

Diskette write protected

Diskette write-protect feature
enabled.

Move the write-protect tab on the diskette to disable the write-protect
feature.

Drive not ready

Faulty or improperly inserted diskette. Insert the diskette properly in the diskette drive, or replace the

diskette.

Embedded server management error

Embedded server management
memory may be temporarily corrupted.

To clear the embedded server management memory, shut down the
system, disconnect the power cords, wait approximately 30 seconds,
reconnect the power cords, and then restart the system. If the
problem persists, see "

Getting Help

."

Embedded server management is not

present

Error: DRAC III initialization failure

Faulty remote access card or I/O
board.

Ensure that the remote access card is properly installed. If the problem
persists, replace the remote access card (see "

Installing an Expansion

Card

" in "Installing System Options").

Error: DRAC III cannot be used with an

add-in video card, system halted

The system supports only the
embedded video when using a remote
access card.

Remove the add-in video expansion card (see "

Removing an Expansion

Card

" in "Installing System Options").

Error: DRAC III is not in the correct

PCI slot, system halted

The remote access card is not in PCI
slot 1.

Install the remote access card in PCI slot 1 (see "

Installing an

Expansion Card

" in "Installing System Options").

Error: More than one DRAC III detected,

system halted

The system supports only one remote
access card.

Remove the remote access card(s) not in PCI slot 1 (see "

Removing an

Expansion Card

" in "Installing System Options").

Extended Security Enabled!

Extended Security is enabled in the
System Setup program.

See "Using the System Setup Program" in the User's Guide.

Failed to copy memory Banks 1 & 2 to

Banks 3 & 4 in Mirror mode

Faulty or improperly installed memory
modules.

See "

Troubleshooting System Memory

" in "Troubleshooting Your

System."

Gate A20 failure

Faulty keyboard controller; faulty I/O
riser card.

See "

Troubleshooting the I/O Riser Card

" in "Troubleshooting Your

System."

General failure

Operating system corrupted or not
installed properly.

Reinstall the operating system.

I/O card parity interrupt at address

Faulty or improperly installed
expansion card.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your

System."

IMB bus error

Faulty or improperly installed I/O
board or microprocessor board.

See "

Troubleshooting the I/O Board

" and "

Troubleshooting the

Microprocessor Board

" in "Troubleshooting Your System."

Insufficient number of power supplies

detected, system halted.

Insufficient power is being supplied to
the system; specified power supply is
improperly installed, faulty, or missing.

See "

Troubleshooting Power Supplies

" in "Troubleshooting Your

System."

Invalid configuration information -

please run SETUP program

Incorrect configuration settings in
System Setup program; NVRAM_CLR
jumper is installed; faulty system
battery.

Check the System Setup configuration settings (see "Using the System
Setup Program" in the User's Guide). Remove the NVRAM_CLR jumper
(see

Figure A

-2

for jumper location). If the problem persists, see

"

Troubleshooting the System Battery

" in "Troubleshooting Your

System."

Advertising