Invalid ESCD Configuration, Resources

Reallocated

System configuration data has been
ignored.

Check the System Setup configuration settings (see "Using the System
Setup Program" in the User's Guide).

Invalid SCSI Configuration; Daughter

Card Detected, SCSI cable not present

on connector A of the primary

backplane.

SCSI cable is loose, improperly
connected, or faulty.

Check the SCSI cable connection. If the problem persists, add or
replace the SCSI cable (see "

Getting Help

").

Invalid SCSI Configuration; Daughter

Card Detected, SCSI cable not present

on connector B of the primary

backplane.

Invalid SCSI Configuration; Daughter

Card Not Detected, SCSI cable present

on connector B of the primary

backplane.

SCSI channel B cable present;
backplane daughter card is not
installed.

Install the SCSI backplane daughter card (see "

Getting Help

").

Invalid SCSI Configuration; SCSI cable

not present on connector A of the

primary backplane

SCSI cable is loose, improperly
connected, or faulty.

Check the SCSI cable connection. If the problem persists, add or
replace the SCSI cable (see "

Getting Help

").

Keyboard controller failure

Faulty keyboard controller; faulty I/O
riser card.

See "

Troubleshooting the I/O Riser Card

" in "Troubleshooting Your

System."

Keyboard data line failure

Loose or improperly connected
keyboard cable; dirty or faulty
keyboard; faulty keyboard controller;
faulty I/O riser card.

See "

Troubleshooting the Keyboard

" and "

Troubleshooting the I/O

Riser Card

" in "Troubleshooting Your System."

Keyboard failure

Keyboard stuck key failure

Memory address line failure at address,

read value expecting value

Faulty or improperly installed memory
modules; faulty microprocessor board.

See "

Troubleshooting System Memory

" in "Troubleshooting Your

System."

Memory double word logic failure at

address, read value expecting value

Memory high address line failure at

start address to end address

Memory high data line failure at start

address to end address

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address,

read value expecting value

Memory allocation error

Faulty application program.

Restart the application program.

Memory bank population error!

Memory modules installed are not the
same type and size in each bank;
faulty memory module(s); memory
modules are not installed sequentially.

Ensure that all banks contain memory modules of the same type and
size and that they are properly installed. Ensure that banks are
populated sequentially (see "

Memory Module Installation Guidelines

" in

"Installing System Options"). If the problem persists, see
"

Troubleshooting System Memory

" in "Troubleshooting Your System."

Memory parity failure at start address

to end address

Faulty or improperly installed memory
modules.

See "

Troubleshooting System Memory

" in "Troubleshooting Your

System."

Memory parity error at address

Memory parity interrupt at address

Memory tests terminated by keystroke

POST memory test terminated by
pressing the spacebar.

No action is required.

No boot device available

Faulty or missing CD/diskette drive
subsystem, hard drive, or hard-drive
subsystem.

See "

Troubleshooting the Diskette Drive

," "

Troubleshooting a CD

Drive

," and "

Troubleshooting Hard Drives

" in "Troubleshooting Your

System."

No boot sector on hard-disk

No operating system on hard drive.

Check the hard-drive configuration settings in the System Setup
program (see "Using the System Setup Program" in the User's Guide).

No microcode update loaded for

Processor n

BIOS error.

Update the BIOS firmware (see "

Getting Help

").

No timer tick interrupt

Faulty I/O board.

See "

Troubleshooting the I/O Board

" in "Troubleshooting Your System."

Non-system disk or disk error

Faulty diskette, diskette/CD drive
assembly, hard drive, or hard-drive
subsystem; no operating system on
diskette or hard drive.

Use a bootable diskette. If the problem persists, see "

Troubleshooting

the Diskette Drive

," "

Troubleshooting a CD Drive

," and

"

Troubleshooting Hard Drives

" in "Troubleshooting Your System."

Not a boot diskette

No operating system on diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion card(s);
faulty or improperly installed
expansion card.

Ensure that all appropriate cables are securely connected to the
expansion cards. If the problem persists, see "

Troubleshooting

Expansion Cards

" in "Troubleshooting Your System."

PCI bus error

Faulty or improperly installed
expansion card; faulty I/O board.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your

System."

Plug & Play Configuration Error

Embedded xxx

Error encountered in initializing PCI
device; faulty I/O board.

Install the NVRAM_CLR jumper and reboot the system. If the problem
persists, see "

Troubleshooting Expansion Cards

" in "Troubleshooting

Your System."

Plug & Play Configuration Error PCI

Slot n

Error encountered in initializing PCI
adapter.

Primary backplane is not present

SCSI cable is loose, improperly
connected, or faulty.

Check the SCSI cable connection. If the problem persists, add or
replace the SCSI cable (see "

Getting Help

").

Processor VID mismatching/VRM missing

Faulty, unsupported, or missing VRM

Ensure that supported VRMs of the same type are properly installed. If