Table 2-4. Diagnostic Indicator Codes 

 

Code

 

Causes

 

Corrective Action

Possible processor failure.

See "

Troubleshooting the Microprocessor

" in "Troubleshooting Your System."

Memory failure.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

Possible expansion card failure.

 

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

Possible video card failure.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

Diskette drive or hard drive failure.

Ensure that the diskette drive and hard-drive are properly connected. See
"

Installing Drives

" for information on the drives installed in your system.

Possible USB failure.

See "

Troubleshooting a USB Device

" in "Troubleshooting Your System."

 

No memory modules detected.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

 

System board failure.

See "

Getting Help

."

 

Memory configuration error.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

 

Possible system board resource
and/or system board hardware
failure.

See "

Troubleshooting IRQ Assignment Conflicts

" in "Troubleshooting Your System."

If the problem persists, see "

Getting Help

."

 

Possible expansion card failure.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

Other failure.

Ensure that the diskette drive, optical drive, and hard drives are properly
connected. See "Troubleshooting Your System" for the appropriate drive installed
in your system.

If the problem persists, see "

Getting Help

."

The system is in a normal operating
condition after POST.

Information only.