Read element status – b8h, What the library does with this command, Command usage – Dell PowerVault ML6000 User Manual

Page 68: Read element status cdb format, Table 57 read element status cdb format

Advertising
background image

58

SCSI Commands

Read Element Status – B8h

What the Library Does With This Command

The library returns current status and information regarding the requested elements. The data is primarily
derived from having done an Inventory operation (using INITIALIZE ELEMENT STATUS or INITIALIZE
ELEMENT STATUS WITH RANGE), but in the case of data transfer elements is also augmented by
communication with the drives. Element status remains valid as long as the subsystem integrity has not
been breached, such as by opening a door or through a power cycle.

Element status will be reported for all elements, including those represented by only a placeholder, as in the
case of uninstalled drives or magazines that physically have a place reserved in the configuration. As such,
it is important to process the fields governing accessibility and exception conditions.

Command Usage

This command should be issued whenever new element status information is needed, or the library has
indicated that status may have changed. If the status information is suspect, an INITIALIZE ELEMENT
STATUS WITH RANGE command should be issued to refresh it.

Read Element Status CDB Format

The READ ELEMENT STATUS CDB format is shown in the following table.

Volume Tag (VolTag) – This field indicates whether the volume tag (bar code label) information should be
returned. A value of one will return the labels, a value of zero will not.

Table 57

READ ELEMENT STATUS CDB format

Bit

Byte

7

6

5

4

3

2

1

0

0

Op Code (B8h)

1

Logical Unit Number

VolTag

Element Type Code

2

Starting Element Address

3

4

Number of Elements

5

6

Reserved

CurDat

a

DVCID

7

Allocation Length

9

10

Reserved

11

Control

Advertising