Storage element descriptor, Table 62 storage element descriptor – Dell PowerVault ML6000 User Manual

Page 73

Advertising
background image

PowerVault ML6000 SCSI Reference Guide

63

Additional Sense Code Qualifier – If the element is in an abnormal state, this field will be set to a value
as described in

Table 71

on page 72.

Source Valid (Svalid) – This field is set to 1 if the Source Storage Element Address field is valid, otherwise
it is set to 0.

Invert – This field is set to 0. The library does not support inverting media.

Source Storage Element Address – If the Source Valid field is set to 1, this field will contain the element
address of the last storage element the media was in. Since the medium transport element cannot be a
destination element, this would be an abnormal condition.

Primary Volume Tag – This field will normally return spaces if the primary volume tag is requested, since
the medium transport element cannot be a destination element. In certain error situations, a volume tag will
be returned to indicate which cartridge may be stranded within the picker.

Storage Element Descriptor

Element Address – This field contains the element address of the storage element.

Access – This field is set to 1 if access by a medium transport element is allowed. It is set to 0 if access is
denied.

Except – This field is set to 1 if the element is in an abnormal state. Additional information may be available
in the Additional Sense Code and Additional Sense Code Qualifier fields. If this field is 1, the primary volume
tag information could be invalid. This field is set to 0 if the element is in a normal state.

Full – This field is set to 0 if the element does not contain media. It is set to 1 if it does.

Additional Sense Code – If the element is in an abnormal state, this field will be set to a value as described
in

Table 71

on page 72.

Table 62

Storage Element Descriptor

Bit

Byte

7

6

5

4

3

2

1

0

0

Element Address

1

2

Reserved

Access

Except

Rsvd

Full

3

Reserved

4

Additional Sense Code

5

Additional Sense Code Qualifier

6

Reserved

8

9

Svalid

Invert

Reserved

10

Source Storage Element Address

11

12

Primary Volume Tag Information

(Field omitted if PVolTag = 0; remaining fields move up)

47

48

Reserved