Configure scsi or fibre parameters, Configuring scsi and fibre parameters – Dell PowerVault 132T LTO/SDLT (Tape Library) User Manual

Page 43

Advertising
background image

 

Configuring SCSI and Fibre Parameters

SCSI/Fibre allows you to set IDs for the library and drives, configure host access, and set emulation mode. If you have a fibre library, you can set the fibre loop
ID, speed, and topology by means of this menu.

Path:

Set Drive SCSI IDs

The SCSI IDs of the drives identifies which IDs the drives use to communicate with the host.

Step 1 From the Setup menu, highlight

and press

.

Step 2 Press

and

to select IE.

Configures IE slot.

Step 3 Press

to move to the next field.

  

Step 4 Press

and

to select

configuration option.

Available options are:

l

ST: appears as a valid storage location
to the host application (host will see
24 data slots for LTO or 21 for SDLT-
320).

l

IE: host will see one import/export slot
and 23 data slots for LTO or 20 for
SDLT-320. If partitioning is enabled,
this slot must be configured "IE" and
not "ST".

Step 5 Press

to highlight Run (

) and

then press

.

The IE slot is configured.

Step 6 A confirmation screen displays. Press

to dismiss.

  

Selection

Description/Result

  

Step 1 From the Setup menu, highlight

and press

.

 

Step 2 Highlight

and press

.

Sets the drive SCSI IDs.

Step 3 Press

and

to select the ID you

would like to set for the Drive 1.

You must choose a number between 0 and
15. The default ID is 1.

Step 4 If you have two drives installed,

press

to highlight Drive 2.

  

Step 5 Press

and

to select the ID you

would like to set for the Drive 2.

You must choose a number between 0 and
15. Ensure that this ID is different from the
ID you set for Drive 1. The default ID is 2.

Advertising