Safety and EMC Standards

Power

 

Thermal Environment

Mechanical Environment

Non-Operating Shock and Vibration

Operating Shock and Vibration

Safety

CSA Standard CAN/CSA-C22.2 no. 950-95
UL Standard 1950, Third Addition
EN60950

Emissions FCC #47, Part 15, Subpart B, Class A;

ICES-003 (Canada);VCCI Class A (Japan);
BSMI CNS 13438 (Taiwan);
EN55022:1994; EN61000-3-2:2001;
EN61000-3-3:1998 (Europe);
AS/NZS 3548:1995 (Australia/NZ)

Immunity EN 55024:1998 ITE – Immunity Characteristics, Limits & Methods of Measurement;

European Union CE Immunity Standards

Input Power

100–240 VAC, 50–60 Hz, 4.0–1.7 A

Power
Consumption
(includes barcode
scanner,
RMU, SCSI
Terminators)

RMS Power
(W)

Peak Power
(W)

 

LTO-1

LTO-2

LTO-3

SDLT

LTO-1

LTO-2

LTO-3

SDLT

One Drive

104

89

76

104

162

147

122

157

Two Drives

179

149

123

179

290

260

210

280

Two Drives with
SNC

253

223

197

253

376

346

296

366

  

Operating

Non-operating

Shipping & Storage

Dry Bulb Temperature 10ºC to 38ºC

(50ºF to 100ºF)
@2000 M
10ºC to 33ºC
(50ºF to 91ºF)
@3000 M

10ºC to 45ºC
(50ºF to 113ºF)

-40ºC to 65ºC
(-40ºF to 149ºF)

Temperature Variation 3ºC (5.5ºF)

per Minute Max

3ºC (5.5ºF)
per Minute Max

3ºC (5.5ºF)
per Minute Max

Wet Bulb Temperature 29ºC (84ºF)

Max

32ºC (90ºF)
Max

37ºC (99ºF)
Max

Relative Humidity

10 to 90%

10 to 90%

10 to 95%

Swept Sine

Range

Peak G

Desktop & Rackmount 3-500-3

1.0

Random Vibration

Frequency

G2/Hz

Desktop &
Rackmount

2
4
8
40
55
70
200
500

1.0x10 -3
3.0x10 -2
3.0x10 -2
3.0x10 -3
1.0x10 -2
1.0x10 -2
1.0x10 -3
1.0x10 -3

Shock

Pulse Amplitude (G) Pulse Width

Desktop
V
H
Rackmount
V
H

  

150
100
  

100
100

  

2
2
  

3
3

Advertising