Dell DR4000 User Manual
Page 27

About Your System
27
Embedded NIC
x and
NIC
y:
OS NIC=
<ENABLED
|DISABLED>,
Management
Shared NIC=
<ENABLED
|DISABLED>.
The OS NIC interface is set
in BIOS. The Management
Shared NIC interface is set
in management tools.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Mouse or keyboard cable is
loose or improperly
connected.
Reseat the mouse or
keyboard cable.
Defective mouse or keyboard. Ensure that the mouse or
keyboard is operational.
Gate A20 failure. Faulty keyboard controller;
faulty system board.
Invalid
configuration
information -
please run SETUP
program.
An invalid system
configuration caused a
system to stop responding.
Run the System Setup
program and review the
current settings. See "Using
Invalid PCIe card
found in the
Internal_Storage
slot!
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.
Remove the PCIe expansion
card and install the
integrated storage controller
in the dedicated slot. See
Keyboard fuse has
failed.
Overcurrent detected at the
keyboard connector.
Message
Causes
Corrective Actions
book.book Page 27 Friday, January 6, 2012 2:11 PM