Appendix b: using sips, Acs console server port pinouts – Dell KVM 4322DS User Manual
Page 167

B
Appendix B: Using SIPs
xxx
|
xxx
157
Appendix B: Using SIPs
An administrator can choose between the Avocent ACS console server and
Cisco pinouts for each serial SIP port via the local user interface or the remote
OBWI. ACS is the default.
To change the pinout to Cisco mode:
1
Select Unit View - RCS - RCS Settings - Ports - SIPs.
2
Click on the desired SIP.
3
Select Settings - Pinout.
NOTE: If the DB-9 adaptor is used, select the ACS console server pinouts.
ACS Console Server Port Pinouts
The following table lists the ACS console server serial port pinouts for the SIP.
Pin No.
Signal Name
Input/Output
1
RTS - Request to Send
OUT
2
DTR - Data Terminal Ready
OUT
3
TXD - Transmit Data
OUT
4
GND - Signal Ground
N/A
5
CTS - Clear to Send
IN
Table B.1: ACS Console Server Serial Port Pinouts