Dell PowerVault MD3200 User Manual

Page 23

Advertising
background image

Hardware Installation

23

a

Install the software and driver package included on the PowerVault

MD series resource media.
For information about installing the software, see "Installing

PowerVault MD Storage Software" on page 27.

b

Update the storage array RAID controller module firmware and

NVSRAM to the latest versions available at

dell.com/support, using

PowerVault MDSM

.

c

Click Tools Upgrade RAID Controller Module Firmware in the

Enterprise Management Window (EMW).

4 Stop all I/O and turn off the system and attached units.

a

Stop all I/O to the array and turn off the host systems attached to the

storage array.

b

Turn off the storage array.

c

Turn off the expansion enclosure(s) in the affected system.

5 Cable the expansion enclosure(s) to the storage array.
6 Turn on attached units:

a

Turn on the expansion enclosure(s). Wait for the enclosure status

LED to light blue.

b

Turn on the storage array and wait for the status LED to indicate that

the unit is ready:
• If the status LEDs are solid amber, the storage array is still coming

online.

• If the status LEDs are blinking amber, there is an error that can be

viewed using the PowerVault MDSM.

• If the status LEDs are solid blue, the storage array is ready.

c

When the storage array is online and ready, turn on any attached host

systems.

7 After the PowerVault MD1200 series expansion enclosure is configured as

an expansion enclosure of the storage array, restore the data that was

backed up in step 1.

After the PowerVault MD1200 series expansion enclosures are online, they

can be accessed as a part of the storage array.