Dell OptiPlex GX1 User Manual

Page 136

Advertising
background image

Messages and Codes: Dell OptiPlex GX1 Small-Form-Factor System User's Guide

file:///C|/infodev/2013/eDoc/OpGX1/UG/messages.htm[2/21/2013 11:47:24 AM]

Table 2. System Beep Codes

Code

Cause

Action

1-1-2

Microprocessor register
failure

See "

Getting Help

" for instructions on obtaining technical assistance.

1-1-3

NVRAM

Run the

System Set Test Group

in the Dell Diagnostics.

1-1-4

ROM BIOS checksum
failure

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

1-2-1

Programmable interval
timer

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

1-2-2

Direct memory access
(DMA) initialization
failure

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

1-2-3

DMA page register
read/write failure

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

1-3

Video Memory Test
failure

Run the

Video Test Group

in the Dell Diagnostics.

1-3-1
through
2-4-4

DIMMs not being
properly identified or
used

See "

Troubleshooting System Memory

."

3-1-1

Slave DMA register
failure

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

3-1-2

Master DMA register
failure

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

3-1-3

Master interrupt mask
register failure

See "

Getting Help

" for instructions on obtaining technical assistance.

3-1-4

Slave interrupt mask
register failure

See "

Getting Help

" for instructions on obtaining technical assistance.

3-2-2

Interrupt vector loading
failure

See "

Getting Help

" for instructions on obtaining technical assistance.

3-2-4

Keyboard Controller
Test failure

Run the

Keyboard Controller Test

in the Dell Diagnostics.

Otherwise, see "

Getting Help

" for instructions on obtaining technical

assistance.

3-3-1

NVRAM power loss

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

3-3-2

NVRAM configuration

Run the

System Set Test Group

in the Dell Diagnostics, if possible.

3-3-4

Video Memory Test
failure

Run the

Video Test Group

in the Dell Diagnostics.

3-4-1

Screen initialization
failure

Run the

Video Test Group

in the Dell Diagnostics.

Advertising