Table 2.

Software

OPERATING SYSTEM

Red Hat Enterprise Linux (RHEL) 6.3z

KERNEL VERSION

2.6.32-279.14.1.el6.x86_64

FILE SYSTEM

Red Hat Scalable File System (XFS) 3.1.1-7

SYSTEMS MANAGEMENT

Dell OpenManage Server Administrator 7.1.2

Firmware and Drivers

BIOS

1.3.6

iDRAC

1.23.23 (Build 1)

PERC H710/PERC H810

FIRMWARE

21.1.0-0007

PERC DRIVER

megasas 00.00.06.14-rh1

INFINIBAND FIRMWARE

2.11.500

INFINIBAND DRIVER

Mellanox OFED 1.5.3-3.1.0

The baseline described in this section is very similar to the Dell NSS. One key difference is the use of a
single RAID controller to connect to all four storage arrays. In a pure-NSS environment, two PERC RAID
controllers are recommended for optimal performance. With two PERC cards, the two RAID virtual disks
are combined using Linux Logical Volume Manager (LVM). DFC does not support caching of an LVM
device, hence a single PERC was used for this study.

The NFS server and the attached storage arrays are configured and tuned for optimal performance
based on several past studies

4

. A summary of the design choices is provided in Section 2.4.

Detailed instructions on configuring this storage solution are provided in Appendix A: Step-by-step
configuration of Dell Fluid Cache for NFS.

2.2. Dell Fluid Cache for DAS based solution

The DFC-based NFS solution builds on top of the baseline configuration described in Section 2.1. It
simply adds PCIe SSDs and the DFC software to the baseline configuration. Details of the configuration
are provided in Table 3 and Table 4.