Beep codes – Dell XPS 600 User Manual

Page 11

Advertising
background image

Advanced Troubleshooting: Dell XPS 600 Service Manual

adtshoot.htm[4/10/2014 9:50:46 PM]

A possible expansion

card failure has

occurred.

1. Determine if a conflict exists by removing a card (not a graphics card) and

restarting the computer (see "

Cards

").

2. If the problem persists, reinstall the card that you removed, remove a

different card, and then restart the computer.

3. Repeat this process for each card. If the computer starts normally,

troubleshoot the last card removed from the computer for resource

conflicts.

4. If the problem persists, see "Contacting Dell" in your Owner's Manual for

instructions on obtaining technical assistance.

Another failure has

occurred.

Ensure that the cables are properly connected to the system board from

the hard drive, CD drive, and DVD drive (see "

CD/DVD Drive

").

If there is an error message on your screen identifying a problem with a

device (such as the floppy drive or hard drive), check the device to make

sure it is functioning properly.

The operating system is attempting to boot from a device (such as the

floppy drive or hard drive); check system setup (see "

Boot Sequence

") to

make sure the boot sequence is correct for the devices installed on your

computer.

If the problem persists, see "Contacting Dell" in your Owner's Manual for

instructions on obtaining technical assistance.

Beep Codes

Your computer might emit a series of beeps during start-up if the monitor cannot display errors or problems. This series of

beeps, called a beep code, identifies a problem. One possible beep code (code 1-3-1) consists of one beep, a burst of three

beeps, and then one beep. This beep code tells you that the computer encountered a memory problem.

Reseating the

memory modules

may fix the beep code errors in the following table. If the problem persists, see "Contacting

Dell" in your Owner's Manual for instructions on obtaining technical assistance.

Code

Cause

1-3-1 through 2-4-4 Memory not being properly identified or used
4-3-1

Memory failure above address 0FFFFh

If you hear one of the following beep codes, see "Contacting Dell" in your Owner's Manual for instructions on obtaining

technical assistance.

Code Cause
1-1-2 Microprocessor register failure
1-1-3 NVRAM
1-1-4 ROM BIOS checksum failure
1-2-1 Programmable interval timer
1-2-2 DMA initialization failure
1-2-3 DMA page register read/write failure
3-1-1 Slave DMA register failure
3-1-2 Master DMA register failure
3-1-3 Master interrupt mask register failure
3-1-4 Slave interrupt mask register failure
3-2-2 Interrupt vector loading failure
3-2-4 Keyboard Controller Test failure

Advertising