Fireplace installation requirements - sdvr – Vermont Casting 2996 User Manual

Page 24

Advertising
background image

24

Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

20003457

26"

(660mm)

16"

(406mm)

ST379a

Transition
Connector

Fig. 45 SDVR minimum lintel height for flush or forward placement.

26"

(660mm)

20

¹⁄₂

"

(521mm)

ST380a

Transition
Connector

Fireplace Installation Requirements - SDVR

6"

(152mm)

20

¹⁄₂

"

(521mm)

26"

(660mm)

*

Existing Wood Stove
Chimney Pipe

Finished
Combustible Wall

ST713a

* Transition pipe must be at least 6”
(152mm) from any combustible material.

Fig. 46 SDVR installations using existing wood stove chimney pipe.

X

Existing Vent Pipe

Transition Connector

Field
Fabricated Cover

ST714

“X” must be 6” (151mm) from any combustible material
unless completely covered by field fabricated sheet metal. If
3” vent pipes are covered by sheet metal, the clearance to
combustibles may be 2” (51mm).

Fireplace Installations Using Existing Wood Stove Chimneys