Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

20003457

9"

(230mm)

Max. Mantel

Width

See

Fig. 6

6"

(150mm)
Sidewall/

Trim

2

¹⁄₂

"

(63mm)

Rear Wall

9"

(230mm)

Max. Mantel

Width

See

Fig. 6

6"

(150mm)
Sidewall/

Trim

2

¹⁄₂

"

(63mm)

Rear Wall

Alcove Installation

Fig. 5 Alcove installation.

ST381

PDV20

ST381a

SDVR

Hearth Requirements

The PDV20 and SDVR Heaters must be installed on
rigid flooring. When the heater is installed directly on
any combustible surface other than wood flooring, a
metal or wood panel extending the full width and depth
of the unit must be used as the hearth. There are no
other hearth requirements.

Weight: Fully assembled 350 lbs.

Gas Specifications

Max.

Min.

Input

Input

Model

Fuel

Gas Control

BTU/h

BTU/h

PDV20RN

Nat

Millivolt

21,000

15,500

PDV20RP

Prop

Millivolt

21,000

16,500

PDV20RFN

Nat

Comfort Control

21,000

15,500

PDV20RNP

Prop

Comfort Control

21,000

16,500

SDVRRN

Nat

Millivolt

21,000

15,500

SDVRRP

Prop

Millivolt

21,000

16,500

SDVRRFN

Nat

Comfort Control

21,000

15,500

SDVRRFP

Prop

Comfort Control

21,000

16,500

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10” w.c.

Gas Inlet and Manifold Pressures

Mantel Clearances

Combustible
Mantel or Trim
Materials

Noncombustible
Materials

A

B

3" (75mm) Min.

ST382

A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater

PDV20 and SDVR

A (Max.)

B (Min.)

9”

10

¹⁄₂

(230mm)

(270mm)

7

¹⁄₂

9”

(190mm)

(230mm)

6”

7

¹⁄₂

(152mm)

(190mm)

4

¹⁄₂

6”

(114mm)

(152mm)

3”

4

¹⁄₂

(76mm)

(114mm)

1

¹⁄₂

3”

(38mm)

(75mm)

Fig. 6 Mantel / top trim clearances.