Stove disassembly, Wiring diagrams – Vermont Casting 2996 User Manual

Page 40

Advertising
background image

40

Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

20003457

FAN JUNCTION BOX

FAN

Strain Relief

Chassis Ground

BLK

GRN

GRN

WHT

ON / OFF
Rheostat

Chassis
Ground

Snapstat

BLK

BLK

BLK

BLK

BLK

WHT

RHEOSTAT / SNAPSTAT

BOX

POWER

CORD

Fig. 83 PDV20/SDVR fan circuit.

MOTOR

SNAPSTAT

ON/OFF
RHEOSTAT

WHT

WHT

BLK

BLK

BLK

GRN

BLK

Schematic Diagram

ST234

ST153

Stove Disassembly

If there is ever a need to remove the firebox assembly
from the stove shell, support the firebox with solid
stands about 6” (150mm) tall under the left and right
outer edges of the firebox base. Do not set the firebox
assembly directly on the floor; this can damage the
control valve and/or the gas lines from the valve to the
firebox.

Before removing the firebox from the shell, disconnect
the on/off switch wires from the valve. If the assembly
includes the optional fan, disconnect the fan rheostat. If
the installation includes a wall thermostat, disconnect
the thermostat leads from valve.

Disconnection and reconnection to the gas line should
only be done by a qualified gas service technician.

Upon reinstallation, the vent system must be sealed to
the firebox as shown in the installation section, page
18. Also be sure the logs are placed in the firebox
correctly, as shown in Figures 51-54, page 27.

NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-
PLIED WITH THE APPLIANCE, MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE SF-
2, 200

°

C WIRE OR ITS EQUIVALENT.

Wiring Diagrams

ST124c

Fig. 82 PDV20/SDVR on/off switch and optional thermostat
circuit.

Optional Thermostat
Wiring

On/Off Switch
Wiring

ST124b

OFF

ON

Thermopile

Black

Black

TP/TH

TP

TH

Thermostat

(Optional)

Therm

opile

Black

Black

TP/TH

TP

TH

Advertising