Operation

The Stardance may be operated with the solid front
plate in place or with the operable door front plate in
place with the doors open or closed. To open the front
doors, insert the handle into the door latch stub and
turn it to the left and up. (Fig. 55) When not in use, the
handle may be stored in the handle holder on the right
side of the rear shroud. (Fig. 56)

Your First Fire

Read these instructions carefully and familiarize
yourself with the burner controls shown in Figure 57.
Locate the pilot assembly, Figure 58. Follow the
lighting instructions on Page 30 exactly.

During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being
heated. Odors should dissipate within a few hours. You
can open a window to provide fresh air to alleviate the
condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot
flame and burner flame pattern are as shown in Figures
60 through 64. If flame patterns are incorrect, turn the
heater off. Contact your dealer or a qualified gas
technician for assistance. Do not operate the heater
until the pilot flame is correct.

Follow regular maintenance procedures as described
on Page 38.

Clockwise to
Open

Counterclockwise

to Close

ST621

Fig. 55 To open the front doors, turn handle clockwise.

Handle
Holder

ST624

Fig. 56 When not in use, store handle in the handle holder.

PILOT

ON

OFF

PILOT

ADJ

LO

HI

TPTH

TH

TP

Piezo Ignitor
Button

Pressure Tap

Regulator
Control Knob

Gas Control Knob

Pilot Adjustment
Screw

HV104

Fig. 57 RN & RP valve control.

Flame & Temperature Adjustment

For stoves equipped with HI/LO valves, flame
adjustment is accomplished by rotating the HI/LO
adjustment knob located near the center of the gas
control valve. (Fig. 59)

LO

HI

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

Fig. 59 Flame adjustment knob for Honeywell valve.

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and the burner flames. Compare them to
Figures 60 through 64.

If any of the flames appear abnormal call a service
person.

Fig. 58 Pilot Assembly location.

Pilot