Qmark EFF - Ceiling Mounted Fan-Forced Heaters User Manual

F” series, Ceiling mounted fan-forced heater, Renewal parts identification

Advertising
background image

Accessories

Cat. No.

Description

F-PE

Pneumatic/Electric Switch. Factory set at 10 psig (69 kPa) to
“make” on pressure drop. May be field wired to “break” on
pressure drop. Pressure set point adjustable to 30 psig
(207 kPa).

F-R2 (24V)

Time Delay Relay. 45-60 seconds to close when energized.

F-R12 (120V) Uses 120V or 24V power supply from remote source.

F-TBF

T-Bar Frame Kit.

FF-SM

Surface Mounting Frame for surface installations.
Painted White.

F-T1

Single pole built-in thermostat kit.

FF-T2

Double pole built-in thermostat kit.

F-TR4

208/240V Primary Transformer/24V Sec. and 24V Holding
Coil Control Relay.

F-TR7

277V Primary Transformer/24V Sec. and 24V Holding Coil
Control Relay.

Installation of Recessed Mounted

Heater in Plaster Ceiling

1. Determine the desired mounting location of the heater.

2. Cut a 14-1/2 inch (368mm) by 18-3/8 inch (467mm) hole in

the ceiling for the recessed back box, maintain 12 inch
(305mm) minimum distance between edge of hole and adja-
cent wall.

WARNING

THIS INSTRUCTION SHEET CONTAINS VITAL INFORMATION
FOR THE PROPER INSTALLATION, USE, AND EFFICIENT
OPERATION OF THE HEATER. CAREFULLY READ THE MANU-
AL BEFORE INSTALLATION, OPERATION, OR CLEANING OF
THE HEATER. FAILURE TO ADHERE TO THE INSTRUCTIONS
COULD RESULT IN FIRE, ELECTRICAL SHOCK, DEATH, SERI-
OUS PERSONAL INJURY OR PROPERTY DAMAGE. SAVE
THESE INSTRUCTIONS AND REVIEW FREQUENTLY FOR CON-
TINUING SAFE OPERATION AND INSTRUCTING FUTURE
USERS.

1. To prevent a possible electrical shock, disconnect all power

coming to heater at main service panel before wiring or ser-
vicing.

2. All wiring must be in accordance with the National and Local

Electrical Codes and the heater must be grounded as a pre-
caution against possible electrical shock.

3. Verify the power supply voltage coming to the heater match-

es the ratings printed on the heater nameplate before energiz-
ing.

4. Do not install the heater closer than 12 inches (305mm) to

any wall.

5. Do not operate heater without front cover installed.

6. This heater is hot when in use. To avoid burns, do not let

bare skin touch hot surfaces.

7. Do not insert or allow foreign objects to enter any ventilation

or exhaust openings as this may cause an electric shock, fire,
or damage to the heater.

8. To prevent a possible fire, do not block air intakes or exhaust

in any manner. Keep combustible materials, such as boxes,
crates, etc., away from heater.

9. A heater has hot and arcing or sparking parts inside. Do not

use it in areas where gasoline, paint or flammable liquids are
used or stored.

10. Use this heater only as described in this manual. Any other

use not recommenced by the manufacturer may cause fire,
electric shock, or injury to persons.

11. This heater is not approved for use in corrosive atmospheres

such as marine, green house or chemical storage areas.

Specifications

Cat. No.

Volts

Watts

BTU/Hr.

Amps

F-1500

120

1500

51,195

12.5

F-2008

208

2000

6826

9.8

F-2004

240/208

2000/1500

6826/5120

8.3/7.2

F-2007

277/240

2000/1500

6826/5120

7.2/8.2

F-1507

277

1500

5120

5.4

F-4008

208

4000

13,652

19.2

F-4004

240/208

4000/3000

13,652/10,239

16.7/14.4

F-4007

277/240

4000/3000

13,652/10,239

14.4/12.5

F-3007

277

3000

10,239

10.8

F-4804

240/208

4800/3600

16,382/12,287

20.0/17.3

F-4807

277/240

4800/3600

16,382/12,287

17.3/15.0

CONTRACTOR

PLEASE READ AND FOLLOW THESE INSTRUC-
TIONS. LEAVE INSTALLATION INSTRUCTIONS
FOR USER TO READ.

FAN DELAY NOTE: A fan delay is standard on all units. In order to
have the fan delay operate correctly, separate wiring is required
between the heater and the wall thermostat. See warning, page 2.

RISK OF FIRE - DO NOT INSTALL HEATER CLOSER THAN 12
INCHES (305mm) FROM ANY WALL.

RISK OF FALLING - THE HEATER BACK BOX MUST BE
SECURELY MOUNTED TO THE BUILDING STRUCTURE AND
THE BUILDING STRUCTURE MUST BE CAPABLE OF SUP-
PORTING THE HEATER WITH ALL ACCESSORIES. THE
HEATER WEIGHT IS AT LEAST 20 POUNDS (9 kg).