DAYLIGHT OPENING
2 per D.L.O. at quarter points. Install weep baffles over the holes with silicone.
Drill 1/4" diameter weep holes in the horizontal face member at 48" on center or
INTERMEDIATE HORIZONTAL FACE
SECTION IV - FABRICATION
48" O.C.
APPLY BAFFLES WITH A SMALL
AMOUNT OF SILICONE TYPE SEALANT.
Install the exterior glazing gasket into the face member at this time, (WNB9).
Be sure to add 2% to the cut length to prevent gaps at gasket intersections.
See Detail #12 above.
STEP #12
STEP #11
8553 FACE
1/4" DIA.
WEEP
HOLES
L
C
WNB9
See Detail #12 below.
Do not plug the weep holes with silicone.
15/16"
WNB9
Detail #12