Antiwalk block installation, Step #58 step #57, Interior gasket installation – EFCO 955 Series User Manual
Page 41: Step #56 antiwalk block installation

Cut the drive-in wedge gasket (W105) to the height and width D.L.O (+) 2%.
Install the vertical gasket first, then follow with the horizontal gasket.
Install the horizontal removable glass stops to the openings at the head and
intermediate horizontals. See detail #57 above.
STEP #58
STEP #57
LOCATE AT THE
MIDPOINT OF LITE
walk and insert into the deep pocket at midpoint. See the details below.
SECTION VII - GLASS INSTALLATION
Choose the appropriate antiwalk block for the required glass type. Use
block #HN50 at 1/4" glass and #HN53 at 1" glass. Compress the anti-
REQUIRED AT
DEEP POCKET
ONLY
INTERIOR GASKET INSTALLATION
ANTIWALK
BLOCK
ANTIWALK
BLOCK
#HN50 OR
#HN53
#8685 OR
#8652 STOP
STEP #56
ANTIWALK BLOCK INSTALLATION
PAGE #39
Detail #58
Detail #57
Detail #56
the middle of the loops until the gasket is installed.
Insert the ends of the gasket first, then set the middle and proceed to set
CONT.
JDA 9/2000