Placement or Locating the Reverse Osmosis System

Simply place the water system on a level floor, cabinet bottom or horizontal surface.

Always assume for enough space for the system and the storage tank, and tubing to remove, move

and/or adjust for filter and membrane replacement and maintenance.

If mounting the system to a wall, cabinet side or other vertical surface,
Please see the following;

Step 1:

All filter cartridges and membranes for system are preinstalled. If the unit is installed in a
permanent hanging position, a minimum clearance of 2” will be required to allow filter
replacement.

Step 2:

Mark pilot holes using the bracket as a template.

Step 3:

Using a drill bit or punch, drill a hole or punch as a starter hole to catch the mounting screws.

WARNING:

ALTERNATIVE FASTENING METHOD MAY BE REQUIRED FOR PLASTER BOARD,
PARTICLE BOARD OR SIMILAR MATERIAL INSTALLATION. USE SAFETY GLASSES
OR OTHER EYE PROTECTION TO PREVENT POSSIBLE EYE INJURY DUE TO
FLYING PARTICLES.

Step 4:

Set mounting screws (provided) with screw driver. Leave a 1/4” gap between the screw
head and mounting surface to allow the bracket to slide on easily.

Step 5:

Slide the bracket over the screws and hang the unit. Make sure unit is level.
Now make the connections of tubing to/from the system.

strictly for illustration purposes only

Kitchen Faucet

Dispenser/Faucet

of filtered water

Inlet from Cold
Inlet/Supply
Connection
(angle stop
not shown)

Unit Mounted to Wall (option shown)

or Placed on level floor

Go to the Placement or Locating the Storage Tank

Storage Tank on floor

WARNING:

UPON INSTALLATION AN R.O. SYSTEM MAY HAVE TO BE “BURPED” OF ANY AIR IN
THE LINES. UPON COMPLETION OF THE “SYSTEM START-UP AND OPERATION
PROCEDURES”, REVIEW THIS WARNING AND DIRECTIONS ON PAGE 4.2-16.

Note:

The interconnection between the inlet, outlet, drain and tank lines can cause air in the unit at the
RSR control valve. Air in lines, and at this valve, will not allow R.O. to function properly.

Note:

Stored Filtered

Water flows

from Tank

through

Postfilter(s)

before going to

Dispenser/Faucet

for use

Helpful Hint:
Find the enclosed Spanner Wrench
that came with the unit and place it
on top of the bracket.

When finished, roll up this Service
Guide and place on top with wrench.

Take a note of the Model # and
WQA Serial # for the required
warranty registration of this unit.

This Service Guide and the wrench
will come in very handy when it’s
time for filter replacement.