Replacement of uv lamp (if applicable), Ews, inc. / environmental water systems 4.2-17 – Environmental Water Systems RU Series User Manual

Page 17

Advertising
background image

EWS, Inc. / Environmental Water Systems

4.2-17

www.EWSWATER.com office: 702-256-8182 (m-f; 8:30-4:30, pst) fax: 702-256-3744 [email protected]

Register this Product - It is a Requirement for Warranty

Familiarize yourself with the system,
its’ replacement filters and maintenance.

To Register, take note of the Model # and WQA Serial # found on the unit’s
bracket,

Understand your system’s capabilities, put the enclosed Spanner Wrench
and this Service Guide on top of the unit bracket,

See your options in water treatment, for you , your family and your home
by EWS, Inc.

Register Your System
our confidential data base will remind you to replace your filters, use our
enclosed form which you can fax or mail to our offices, or register on-line
at ww.ewswater.com, click the “PRODUCT REGISTRATION” button, then
the link for “Online Interactive Registration”

Step 1:
Unplug the transformer. Then disconnect the UV lamp cord.

NOTE: All R.O. Units with UV Option:

UV module is set on top of bracket (easy access)

Step 2:
Pull firmly on the UV lamp tail only to remove the lamp.
Do Not remove cap at top of UV Module
(If needed, snap the UV module from the bracket clips to
gain access for lamp removal).

Step 3:
Insert and firmly press new UV lamp into the top of the cap.
(If applicable, snap the UV module back into the bracket clips).

Step 4:
Reconnect UV lamp cord. Plug in unit transformer.

Replacement of UV Lamp (if applicable)

strictly for illustration purposes only

1 - Fully Assembled UV Module
2 - UV Module Housing
3 - UV Cap with Quartz Glass Sleeve
4 - UV Lamp with Lamp Cord

1

2

3

4

UV Lamp should be changed annually based on tested results to maintain UV effectiveness.

NOTE: Electrical outlet must be dedicated and unswitched. Be aware of any GFI outlets and the need to reset. Surge

supression highly recommended. Not responsible for bulb that may expire prior to annual service.

WARNING:

DO NOT DISCONNECT UV MODULE FROM THE FACTORY CONNECTIONS AND DO NOT OPEN
UV CAP FROM UV MODULE FOR TYPICAL UV LAMP REPLACEMENT.