Management Commands
AT8901M
AT8901M CLI Reference Manual
Page 6 - 34
application and during normal execution of switching application) and the heartbeat
(sending interval and number of missed heartbeats before failure occurance). All
values (except missed heartbeats) are in seconds, a value “0” means that the related
watchdog is disabled.
Default
disabled (0)
Format
set watchdog bist
<0,30-6000>
set watchdog osloader
<0,120-6000>
set watchdog init
<0,60-6000>
set watchdog application
<0,5-6000>
set watchdog heartbeat
<0,1-6000>
Mode
Privileged EXEC
6.13.2
show watchdog
This command displays the watchdog settings. It displays the values (or string
“disabled”) of different watchdog (during BIST, during loading of kernel and INITRD,
during startup of switching application and during normal execution of switching
application) and the heartbeat of the fpmux application.
Format
show watchdog
Mode
Privileged EXEC