TIGH2U Server—Server Component Installations and Upgrades

Kontron Carrier Grade Server TIGH2U

Product Guide, rev.1.2

December 2009

32

3. With the drive tray locking lever fully open, push the hard drive tray into the drive bay in the

chassis until it stops. (

Figure 16

, “A”)

4. Press the lever until it snaps shut to secure the drive in the bay.
5. Replace the front bezel.

Figure 16.

Inserting a New SAS Drive Assembly

A

TS000275

3.3.2

Replacing a Power Supply

Caution:

Your server does not have a redundant power supply unless you have purchased the

optional second power supply. If there is no second supply, before replacing the power

supply you must first take the server out of service, turn off all peripheral devices

connected to the system, turn off the system by pressing the power button, and unplug

the power cord(s) from the system or wall outlet.

To maintain hot-swap capability, make sure that there is an active power supply module

in both chassis slots before replacing (hot-swapping) a power supply module.

The TIGH2U Server supports the use of either AC (

Figure 17

, “C”) or DC (“D”) power supply modules.