3.3.2.3

Installing or Replacing a DC Power Supply

1. Slide open top of male connector to reveal screw holes. ("A")
2. Strip the wire insulation as shown. Note minimum wire gauge. ("B")

Insert each wire all the way and tighten to 24 in-lb (2.7 N-m) torque. ("C")

Figure 18.

DC Power In Male Connector Configuration

Strip Wire 0.625"
(16mm)

Min. Wire

14 AWG

C

A

B

#2 Phillips*

Screwdriver

3.3.2.4

Grounding a DC-Powered System

The DC chassis provides two #10-32 threaded studs for chassis enclosure grounding. A single 90º

standard barrel, two-hole, compression terminal lug with 5/8-inch pitch suitable for a #14-10 AWG

conductor (such as the Thomas & Betts* terminal lug, p/n 256-31426-141) must be used for proper

safety grounding. See “C” in

Figure 3

for the location of the ground studs.

A crimping tool may be needed to secure the terminal lug to the grounding cable.

3.4

Internal System Component Configuration and Installation

Procedures

Note:

The procedures in this section assume that you have powered down the server and

removed the chassis cover as described in

Section 3.2

,

“General Installation

Procedures”

.

3.4.1

Configuring Jumpers on the Server Board

The jumpers are located on the T5000PAL server board, which is in the rear right section of the

Carrier Grade Server TIGH2U chassis. To configure the jumpers on the server board, you must first

remove the chassis cover, the processor air duct (see

Section 3.2.5

,

“Removing the Processor Air

Duct”

), and the PCI riser card assembly (see

Section 4.2.2, “Removing the PCI Riser Card Assembly”

on page 56

). All other components installed on the server board can remain in place.