Server Component Replacements—TIGH2U Server

3. Place the new fans into the fan assembly bracket with the airflow arrows or the labels if there are

no airflow labels, pointing toward the rear of the chassis.

Note:

It is important to insert the fans in the correct direction. The air must flow from the

front of the chassis to the back.

4. Route the fan power cable through the cut-out on the bottom of the bracket and bring it to the

front corner opening. (

Figure 58

, “A”)

5. Fasten each fan to the bracket with two rivets. (“B”)

Figure 58.

Installing New Fans into the Bracket

TS000458

B

A

5.2.3

Installing the CPU Fan Assembly

1. Position the fan assembly bracket in the chassis. (See

Figure 56

.)

2. Tighten the blue thumbscrew to secure the fan bracket in the chassis. (“B”)
3. Plug the fan power cables back into the SFP board connectors. See “F” on

Figure 35, “System

Cable Routing” on page 53

for the location of these connectors:

— Connect the left fan to connector J7A2 on the SFP board
— Connect the right cable to connector J7A1 on the SFP board

4. If this is the last task you are performing, replace the processor air duct and the chassis top

cover. Reconnect all the external devices and plug in the power cord(s).