ELECTRICAL WIRING

All wiring from the SS1C to the appliance must be appropriate Class 1 wiring as follows: installed in rigid metal conduit, intermediate
metal conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI Cable, Type MC Cable, or be otherwise suitably protected
from physical damage.

SS1C SEQUENCE OF OPERATION WITH INTEGRAL UC1 UNIVERSAL CONTROL:

Control signal from thermostat, aquastat, primary control or gas valve is intercepted and routed to terminal “1” on UC1 terminal
strip. When terminal “1” is energized with either 24 VAC or 120 VAC, the SS1C motor is energized. After draft is established, the
Fan Proving Switch closes within 5 to 10 seconds energizing terminal “4”, which completes the circuit allowing burner to fire.
NOTE: If a venter pre-purge is selected, the burner will not fire until the pre-purge time is finished. The SS1C will continue to run
after the burner has finished firing for the set post-purge time cycle. The SS1C is set for a 2 minute post-purge time period from
the factory. See “Pre / Post-Purge Settings” on page 5 for details.

The "1" input terminal on the SideShot can accept either a 24 VAC or 120 VAC control signal. IMPORTANT: The RED
jumper must be positioned based on appliance interlock voltage. For most furnace applications it may be easier to interlock with
the 24 VAC thermostat circuit. For most boiler applications it may be easiest to interlock with the 120 VAC aquastat or primary
control circuit to the burner motor. Choose the interlock method that best fits your application.

The steps listed under each diagram are intended as a supplement to the diagram. Wiring colors or designations may vary by
manufacturer. If you are unable to wire the SS1C as outlined in these instructions, call Tjernlund’s Customer Service Department
toll free at 1-800-255-4208 for assistance.

IMPORTANT: To reset faults, verify fault by checking the LEDs and then remove call for heat.

SS1C WITH INTEGRAL UC1 UNIVERSAL CONTROL

(THE SS1C MOTOR, LIMIT & PROVER ARE ALL FACTORY PREWIRED)

12

IMPORTANT:
RED JUMPER POSITION MUST BE THE SAME

AS APPLIANCE INTERLOCK VOLTAGE.

CALL

RELAY

INTERLOCK

COMMON

NEUTRAL

PRODUCTS,

INC.

SS1 MOTOR

1 H.P. MAX @ 115 VAC

SUPPLY
115 VAC
50/60 Hz

R

TJERNLUND

9183006

NO

MTR

M

MOTOR

RELAY

N

COM

NO

115 VAC

24 VAC

1303960-1

DO NOT SUPPLY VOLTAGE

TO "A" OR "B".

DO NOT SUPPLY POWER!

5 VDC BOARD-GENERATED POWER

HOT

24 VAC

USER-PROVIDED

CALL SWITCH

LINE

OR

"DRY"

OR

115V

J2

COM

24V

DRY

LEGEND:

115 VAC

5

POST-PURGE SETTINGS

FOR TJERNLUND

TO P1, P2, C, GND

AUXILIARY

OR F. DOING SO

WILL DAMAGE THE

CONNECT POWER

OPEN PROVER OPTION

(9)

(3 - 8)

9

7
8

6

CONTROL.

DEVICES. DO NOT

F

GND

ON

LED1

PRE-PURGE SETTINGS

LED5 LED4

LED2

LED3

(1 - 2)

2

4

3

1

C

P1

P2

J1

XL

XN

115 OR 24 VAC FROM CALL JUMPER
OR USER-PROVIDED VOLTAGE
FROM TERMINAL 3 TO 4 WITH CALL
JUMPER REMOVED

K2

K1

APPROVED

MAC1E OR MAC4E

JUMPER

RED

RED

GREEN

GREEN

AMBER

SS1 PROVER

SS1 LIMIT

WARNING: Disconnect power supply from the SS1C and heating equipment when making wiring connections and servicing the

SS1C. Failure to do so may result in personal injury and/or equipment damage. LED #5 (RED) should be off with
power removed.