Tjernlund SS1C SideShot with UC1 Universal Control (Version X.02) 8504103 Rev 07/02 User Manual

Page 2

Advertising
background image

1

Tjernlund Products welcomes your comments and questions. Address all correspondence to:

Customer Service • Tjernlund Products, Inc. • 1601 Ninth Street • White Bear Lake, MN 55110-6794

Call us toll free at 800-255-4208, visit our web site @ www.tjernlund.com or email us at [email protected].

TABLE OF CONTENTS

Page (s)

Description and Specifications ....................................................................................................................................1, 2
Installation Restrictions .............................................................................................................................................2, 3
Cautions .........................................................................................................................................................................3
Safety Inspection of a Previously Used Appliance .........................................................................................................3
SideShot Model SS1C Terminology ...............................................................................................................................3
SideShot

®

With Integral UC1 Universal Control Board Features ...................................................................................4

LED Status & Fault Indicators .........................................................................................................................................4
Pre / Post-Purge & Prover Status Check Settings...........................................................................................................5
Termination Clearances .................................................................................................................................................6
Installation

Tools Required .................................................................................................................................................7
Vent Hood Installation ..............................................................................................................................7, 8, 9
Installation of Rain Shield .................................................................................................................................8
Plenum Installation .................................................................................................................................8, 9, 10
Installation of Vent Pipe ............................................................................................................................10, 11

Electrical Wiring

Warnings, Sequence of Operation & Internal Schematic ...............................................................................12
Wiring to Oil Fired Equipment ............................................................................................................13, 14, 15

Fan Proving Switch Bleed Orifice Selection ..................................................................................................................16
Draft Adjustment Procedure (Oil) ............................................................................................................................16, 17
Combustion Air ............................................................................................................................................................. 17
System Operation Check Out .......................................................................................................................................18
Troubleshooting Oil Odors.............................................................................................................................................18
Troubleshooting Electrical Problems .......................................................................................................................19, 20
Maintenance ............................................................................................................................................................20, 21

Removal & Replacement of Motor/Wheel ................................................................................................20, 21

Warranty & Replacement Parts ...............................................................................................................................21, 22
Installer Notes................................................................................................................................................................23
Mounting Templates

Template B Motor Notch ................................................................................................................................24
Template A Vent Hood Terminus ....................................................................................................................25

SideShot

®

is a registered trademark of Tjernlund Products, Inc. for their Models SS1 & SS2 Vent Systems.

DESCRIPTION

The SS1C is a mechanical vent system designed and listed for use with natural draft oil heating equipment. It is factory assem-
bled and wired. The SS1C automatically vents the flue gases from heating equipment to the outdoors. By combining outside air
with high-tech insulation, surrounding combustible materials and the Vent Hood exterior remain at safe temperatures. After each
burner cycle the SS1C will continue to operate in post-purge mode to purge the heater and vent of residual flue gases. A factory
post-purge time is set at 2 minutes and is adjustable up 16 minutes, see “Pre / Post-purge Settings” on page 5. The SS1C fea-
tures a safety system consisting of the integral UC1 Universal Control, a Fan Proving Switch and a High Limit temperature control.
These devices monitor the SS1C’s performance and will interrupt the main burner if a venting malfunction is detected.

APPLICATION TABLE

Verify that the total BTU/hr. input of the heating appliance(s) fall within the proper category listed below. All BTU/hr. capacity
ranges are based on a maximum of 15.2 equivalent meters (50 feet). To determine equivalent meters, add the total length of
straight vent pipe plus 3.1 meters (10 feet) for each 90 degree elbow and 1.5 meters (5 feet) for each 45 degree elbow. Vent
runs of over 4.5 linear meters (15 linear feet) should use an approved, insulated vent connector to prevent problems related to
sulfur condensation.