Configure panel options, Double button push, Always override – Vinten Radamec Fusion FCS-16 User Manual

Page 34: Always enable drive, Always disable ir

Advertising
background image

32

Configure panel options

Control panel options can be configured to suit the operator. To access these ‘panel options’, proceed as fol-
lows:

1. Select MENU (35) > SHOW MANAGEMENT > CONFIGURATION.

2. The panel option buttons DOUBLE BUTTON PUSH (51), ALWAYS OVERRIDE (50), ALWAYS ENA-

BLE DRIVE (42), ALWAYS DISABLE IR (43) and ALWAYS DISABLE BUMBERS (44) are toggle but-
tons. Repeatedly selecting these buttons will toggle each function on and off. If a button is coloured
blue then the function is active.

3. Select RETURN (48) to return to the main screen.

Double button push

When DOUBLE BUTTON PUSH (51) is selected, all control panel buttons must be pressed twice to activate
any function.

Always override

If ALWAYS OVERRIDE (50) is selected, the chosen Radamec RP2A pedestal will continue moving at quarter
speed on detection of either an Infrared proximity warning (refer to Always disable IR on page 32) or collision
with an obstacle (refer to Bumper disable on page 31).

Always enable drive

If ALWAYS ENABLE DRIVE (42) is selected, the joystick control panel will have the JOYSTICK ENABLE func-
tion (4) activated by default (refer to Joystick enable on page 30).

The joystick enable button (4) must be depressed and illuminated to move the pedestal around the studio floor
(in X and Y axes) using the pedestal control joystick (16). When the joystick enable button (4) is NOT activated,
the pedestal control joystick (16) only allows robotic height movement. This feature prevents accidental ped-
estal travel while rotating the pedestal control joystick (16) to adjust camera height.

Always disable IR

If ALWAYS DISBLE IR (43) is selected, the infrared proximity protection (which arrests pedestal travel before
contact with an obstacle) is turned off on all connected Radamec RP2A pedestals.

Note:

This function only affects Radamec RP2A pedestals.

WARNING! 1. The ALWAYS OVERRIDE (50) function will have no effect on Radamec

RP2A pedestal proximity detection if the ALWAYS DISABLE IR function (43)
is active.

2. The ALWAYS OVERRIDE (50) Radamec RP2A pedestal function will have
no effect on collision with an obstacle if the ALWAYS DISABLE BUMPERS
(44) function is active.

Note:

This function only affects Radamec RP2A pedestals.

Advertising