Fusion FH-100 and FHR-100 pan and tilt heads

28

4.

Ensure that the head is set to robotic mode (AUTO).

5.

Align the pan and tilt axes to zero position (i.e. align the camera cradle [1] horizontally
and vertically to the head).

6.

Switch ON power to the head.

7.

On the laptop/PC, double-click the Fusion Setup and Test icon on the desktop to
launch the configuration software tool. The Vinten Fusion Robot Control window is
displayed (Fig. 13).

8.

In the Robot Type section (a), select Head.

9.

In the Machine Version section (b), select the 2048 Line Encoder option for the
installed head. For an FH-100 VR head, select the VR option (Fig. 13).

10. Click Zero Pan and Tilt (c) to set the current head position as the ‘zero datum’ in the

software. (The button becomes greyed out during processing of the datum, but
becomes selectable again when processing is complete.)

Fig. 13 Vinten Fusion Robot Control window

(a) Robot Type section, (b) Machine Version section, (c) Zero pan and tilt button,

(d) Set Pan, Tilt X/Y and Height Limits button, (e) Processor Reset button

a

b

d

c

e