Focus calibration – Vinten Radamec HS-2010MED Pan & Tilt Head User Manual

Page 58

Advertising
background image

HS-2010MED

Maintenance And Repair

4-8

User Manual

11. The voltage at JP2 should always be positive. If it goes negative, R4 until it

remains positive throughout the zoom range.

Focus Calibration

12. Measure the voltage at jumper JP3. Adjust R22 (Focus Center) so that the

voltage at JP3 is equal to the lens reference measured in step #6.

13. Monitor the voltage at JP3 and use the focus control on the control panel to

run through the entire zoom range. Adjust R8 (Focus Range) for full travel
of the lens.

14. Reset the focus control for 50.00 in the Real Time Status screen. If neces-

sary, adjust R22 (Focus Center) so that the voltage at JP3 is equal to the
lens reference measured in step #6.

15. Repeat step #13.

16. The voltage at JP3 should always be positive. If it goes negative, R8 until it

remains positive throughout the zoom range.