Inspecting the Venting System

This appliance venting system is designed and
constructed to develop a positive flow adequate to
remove flue gases to the outside atmosphere.

Any foreign objects in the venting system, except those
designed specifically for the venting system, may cause
spillage of flue gases.

To inspect the venting system, make sure the main gas
valve is off. Remove the window frame assembly.
(Refer to Window Frame Assembly Removal section.)
Using a flashlight, check the area above the baffle in
the combustion dome. Clean if necessary.

Glowing Lava Rock

LG231

Fig. 51 Correct burner flame appearance for DVRT43.

5 Flame areas

Glowing Lava Rock

LG230

Fig. 50 Correct burner flame appearance for DVRT39.

5 Separate flames

Glowing Lava Rock

LG229

Fig. 49 Correct burner flame appearance for DVRT36.

3/8" - 1/2"

Fig. 48 Correct pilot flame appearance.

PSE Pilot

SIT Pilot

3/8"-1/2"