Optional Accessories

Fan Kits

Hard (Direct) Wire Hookup

FK-12 Fan Assembly

1. Open lower louvre.

2. Install FK-12 fan in back of unit between hearth

supports. (Fig. 57)

3. Secure fan on Velcro strips.

4. Power to the fan can be supplied by plugging the

supply lead into a conveniently located wall socket
or by using a hard-wired EB-1 connector box.

5. Be sure fan motor does not touch nearby metal.

FK-24 Fan Assembly

Fan specifications: 120 Volt, 60 Hz 75 Amp.

This fan does not require regular maintenance, however
periodic cleaning is required. Check the area under the
control door and in front of the fan and wipe or vacuum
at least once a month during the operating season.

Should this fan require servicing, the power supply
must be disconnected.

The FK-24 comes with the electrical cord attached.

1. Slide fan assembly from the left side into the

fireplace opening, line up mounting holes with
screw studs on back of fireplace and fasten with
#10-24 hex nuts.

2. Install thermal sensor on bottom of firebox using

#10-24 hex nuts.

3. Option A: Place electronic fan speed control box

on bottom of fireplace base, lining up mounting
holes with screw studs. Fasten fan speed control
box with #10-24 hex nuts.

Option B: The speed control can be installed in an
electrical box at normal wall switch height for
convenient access.

4. The power supply may be connected in 2 ways:

First connect ground wire to ground stud located on the
base of either box. Black wire from supply should
connect to the variable speed switch. Alternate speed
switch wire connects to temperature sensor. Alternate
lead from sensor connects to fan. Alternate fan lead
connects back to the white supply wire. (Fig. 59)

Any electrical rewiring of this fan must
be completed by a qualified electrician.

Turn off all power before hookup.

Method A: Route the 6’ (1.8m) lead fitted to the
unit to a conveniently located wall socket.

Method B: If the EB-1 receptacle box (Part #
ZA1200) was correctly connected when the unit was
installed, the fan lead can be directly plugged into
the EB-1 plug socket.

5. Whether wiring directly to the fan junction box

(Option A) or into the EB-1 (electrical receptacle
box, Option B), first ensure cable is secured using
box connector.

The fireplace when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code. For
USA installations, follow local codes and
the National Electrical Code, ANSI/ NFPA
No. 70.

Black

White
Ground

Fig. 59 FK-24 fan wiring.

Fan

FP1025

Speed control

Temperature
sensor

HI

L O

O

FF

ON

O F F

P

IL

O

T

O

FF

E

A

PIL

OT

T

P

T

H

Fig. 58 FK-24 fan placement.

FP1026

Electrical
Box

Heat
sensor

Fan

Fan Speed
Switch

Gas Line

Valve

Fig. 57 FK-12 Fan Kit placement.

Cold Air
Box

FK-12 Fan

FP1004

Front of
Unit

Hearth Pan

Base Pan

Side View