Local path, On path – Vermont Casting DVRT43 User Manual

Page 34

Advertising
background image

34

Vermont Castings, Majestic Products DVRT36/ 39/ 43

10002428

Comfort Valve System Control Sequence of Operation with Transmitter

If manual switch is

set to LOCAL, did

main burner light

and fan turn on?

Turn pilotstat knob

to PILOT to turn

off main burner.

Turn pilotstat knob

to OFF to turn

valve completely

Off.

Local Path

Move switch from

LOCAL to RE-

MOTE. Press any

key on transmitter.

Move switch back

to

LOCAL.

Yes

Light pilot burner

Set manual switch to
LOCAL or REMOTE

Release pilotstat

knob

Turn pilotstat knob

from PILOT to ON

Did the LED stop

blinking?

Review LED

failure analysis.

Five minute wait

period

Cycle switch once

and leave in

REMOTE. Press

any key on

transmitter for

recognition

operation.

If the manual switch

is set to REMOTE,

press the mode

button to display ON.

Does the transmitter

control the main

burner and fan?

Does transmitter

change levels of

flame height

and/ or fan speed?

Set levels of flame

height and fan to

“0” to shut off main

burner and fan.

Turn pilotstat knob
to Off to turn valve

completely off.

On Path

Move switch from

MANUAL to

REMOTE. Press

any key on

transmitter.

Yes

Yes

No

Choose MANUAL or

REMOTE path. Set
switch to MANUAL

or REMOTE.

Yes

Yes

Advertising