Vermont Casting DVRT43 User Manual

Page 33

Advertising
background image

33

10002428

Vermont Castings, Majestic Products DVRT36/ 39/ 43

Auto Path Chart

If the manual switch is

set to REMOTE,

press the mode button

to display AUTO on the

transmitter. Does the

transmitter display the

room and temperature

setting?

If the settings is above

room temperature on

the transmitter, did

the main valve and

fan turn On?

Turn pilotstat knob to

OFF to turn the valve

completely Off.

Auto Path

Move switch from

LOCAL to REMOTE.

Press any key

within 30 seconds.

Yes

Yes

No

No

If the settings is below

room temperature on

the transmitter, did

the main valve and

fan turn Off?

LED Count Service Action

8

Replace valve

7

Confirm stepper motor connection exists

5

Confirm fan connection exists and works

4

Confirm gas type; jumper in place

3

Replace thermopiles

2

Turn fan ON

NOTE: Some keys are not active.