MSDS

V. MSDS
This MSDS is also available at www.nextteq.com as PN 50811320-340N

Part 1 - Material Identification

Material Name: Stannic Chloride Irritant Smoke Generator (PN

50811320-310N)

Chemical Name: Stannic Chloride (CAS No. 7646-78-8, UN No. 1827)

Synonyms:

A. Tin tetrachloride, Tin (IV) Chloride

B. Air Flow Indicator Tube

C. Irritant Smoke Generator

Formula: SnCl

4

Chemical Family: Metal Chloride

Part 2 - Ingredients & Hazards

Stannic chloride reacts with ambient humidity to liberate a white smoke

consisting of hydrogen chloride (HCl) and tin compounds.

The emitted smoke has a strong irritating odor.
Exposure Limits
Tin Inorganic Compounds
ACGIH-TLV: TWA 2 mg/m

3

OSHA PEL: 2 mg/m

3

Hydrogen Chloride
OSHA PEL: Ceiling 5 ppm

ACGIH-TLV: STEL Ceiling 2 ppm

Listed in the 2004 ACGIH-TLV handbook with a carcinogenicity notation

of A4, which is defined as “Not classifiable as a human carcinogen”.

Part 3 - Physical Data

Stannic Chloride
Appearance: Colorless liquid

Boiling Point: 237.2°F