Nextteq VeriFit Irritant Smoke Generators for Respirator Fit Testing User Manual
Page 20

Page 17 of 24
VeriFit Irritant Smoke Generators Manual
Nextteq LLC 8406 Benjamin Road, Suite J, Tampa, FL 33634 USA
PN 50811300-340N Rev F 5/09
Other Precautions: Avoid eye and skin contact with smoke. Do not
directly breathe the smoke. Avoid the buildup of smoke. Use in a well-
ventilated area. Do not use under a hood or in a confined space. Do
not blow smoke directly into anyone’s unprotected face or eyes. Test
only one person at a time. Do not blow smoke between test subjects.
Immediately after using the smoke tube or being exposed to the smoke,
scrub face, hands, and any area exposed to the smoke with soap and
clean running water and always before eating, drinking, smoking,
applying cosmetics, or inserting or removing contact lenses.
Do not use this product for respirator fit testing or a “Sensitivity Check”
if any of the following conditions is present:
A. The test subject has pre-existing respiratory, cardiovascular,
bronchial, or sinus medical condition.
B. The test subject is under a physician’s care for respiratory,
cardioular, bronchial, or sinus problems.
C. The test subject is being treated for allergies, hypersensitivity,
or asthma or has a pre-existing allergic, hypersensitivity, or
other condition.
D. The test subject is allergic to or hypersensitive to hydrogen
chloride, stannic chloride, stannic oxide, stannic dioxide, tin
tetrachloride, tin compounds, hydrochloric acid or metal chloride.
MSDS