If it is desired to change the CDI scale factor to another
value, use the following procedure:

1. Use the left outer knob to select the MODE page.

2. Press the left

C

. If necessary, use the left outer

knob to move the cursor over the value of the CDI
scale (figure 5-121).

NOTE: The OCEANIC:ON/OFF field shown in figures

5-121 and 5-122 will only appear on ORS 04 and later
versions of the KLN 900.

3. Rotate the left inner knob to select the desired CDI

scale factor (figure 5-122).

4. Turn the left

C

off. The CDI scale factor change is

complete.

NOTE: The KLN 900 will automatically select a scale

factor while in one of the approach modes. When the
KLN 900 selects a CDI scale factor it is not possible to
select a scale factor that is less sensitive than what the
KLN 900 has automatically chosen. For example, as
you will see in the next chapter, the approach-arm
mode usually has a scale factor of ±1 NM. While in the
approach-arm mode it is not possible for you to select
the ±5 NM scale factor. This is to ensure proper
operation of the approach modes.

Figure 5-122

Figure 5-121

ACTIVE MODE|
|
OCEANIC:OFF|
LEG |
|
CDI:±

5.00

NM|

CRSR

enr-leg

ACTIVE MODE|
|
OCEANIC:OFF|
LEG |
|
CDI:±

0.30

NM|

CRSR

enr-leg