EdgeAccess Universal Chassis System

L357 Gigabit Ethernet Service Unit

2-2

Table 1. Switch 1 and 2 UTP Speed Settings

Switch 1 Switch 2

Speed

Off Off 1000

Mbps

Off On 100

Mbps

On Off 10

Mbps

On On Autonegotiate

Table 2. Switch 3 Through 8 Functions

Switch Function

On

Off

3

Full Duplex on UTP User Port Select full duplex

Select half duplex

4

SBMC

Enable SBMC

Disable SBMC

5

LLF, Extension to User

Enable Link Loss Forwarding
(LLF) propagating from
Extension Port to User Port

Disable LLF propagating
from Extension Port to User
Port

6

LLF, User to Extension

Enable LLF propagating from
User Port to Extension Port

Disable LLF propagating
from User Port to Extension
Port

7, 8

Not used

4. To install the L357 in a BAM in a UCS 1000 or 1001, follow these steps:

a. Insert a BAM into an available slot. Slide the BAM into the rails and push it firmly into the

connector, then tighten the captive screws. If you encounter resistance, pull the BAM out and
check that no connector pins are bent.

b. Insert the L357 into an unused slot in the BAM. Slide the L357 into the rails and push it

firmly into the connector, then tighten the captive screw. If you encounter resistance, pull it
out and check that no connector pins are bent. If you encounter more difficulty, contact
Canoga Perkins at (800) 360-6642 for technical assistance.

5. To install the L357 in a UCS Model 1002 or Standalone Enclosure, insert the L357 into an

unused slot. Slide the L357 into the rails and push it firmly into the backplane, then tighten the
captive screw. If you encounter resistance, pull it out and check that no connector pins are bent. If
you encounter more difficulty, contact Canoga Perkins at (800) 360-6642 for technical assistance.

Note: The L357 is hot-swappable and can be inserted or removed without disrupting data transfer

in other modules in the chassis.