CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 38

Advertising
background image

EdgeAccess Universal Chassis System

L357 Gigabit Ethernet Service Unit

4-18

4. When you finish running Loopback, press <Esc> to return to the Diagnostics menu, then press

<Esc> to return to the Main Menu

LOOPBACK SETUP
Local Remote
Chassis/Slot 4/3B 2/5

Loopback Switch Setting: N/A N/A

Loop Test MAC Address: 00 40 2A 80 58 32 00 40 2A 80 58 33

1) Loopback Option Control Software Software
2) Loopback State Disabled Disabled
3) Swap MAC Address
at Loopback Point? Yes Yes
4) Recalculate CRC
at Loopback Point? Yes Yes

Figure 29. Diagnostics Screen

Table 9. Diagnostics Screen Definitions

Selection Description

Loopback Switch Setting

Shows hardware setting only when in a Model 1020; Local,
Remote, or Normal

Loop Test MAC Address

Shows unique MAC address for destination of loopback packets

1) Loopback Option Control Set to Hardware (option for Model 1020 only) or Software

2) Loopback State

Set to Local, Remote, or Clear All Loopbacks

3) Swap MAC Address at
Loopback Point?

Set to Yes or No; use to run loopback packets through a switch

4) Recalculate CRC at
Loopback Point?

Set to Yes or No; use to run loopback packets through a switch

4.6.1 Remote Latency/Jitter Test

Use the Remote Latency/Jitter Test report and menu to set up test conditions and view test results for
troubleshooting the L351 and its link partner. To test latency and jitter, follow these steps:

1. From the Diagnostics menu, type 2, Remote Latency/Jitter Test, and press <Enter>. The

Latency/Jitter Test screen appears.

2. Type the number for the test parameter option you want to set, type the value, and press

<Enter>.

3. Type 8 to start the test or type 9 to end the test.

4. When you finish running the Remote Latency/Jitter test, press <Esc> to return to the

Diagnostics screen.

Advertising