6 error counters, 1 utilities screen, Error counters -12 – CANOGA PERKINS 6703 CWDM Transponder User Manual

Page 24: Utilities screen -12, Table 7. link error counters definitions -12

Advertising
background image

EdgeAccess Universal Chassis System

3.6 Error

Counters

The Error Counters screen reports errors that occur on the 6703 link. See Figure 14 and Table 7. To
view the link errors, follow these steps:

1. From the Main menu type

3

, "Error Counters," and press <Enter>. The Error Counters screen

appears.

2. To reset the timer and counters, press <Tab>.

3. To return to the Main Menu, press <Esc>.

ERROR COUNTERS

Timer 0 days 00:05:26

Local Remote Rx1 Remote Rx2

Receive Level 1 201 330
SpeedCop Violations 0 6
CDR Unlock 0 0

Figure 14. Error Counters Screen

Table 7. Link Error Counters Definitions

Item Definition

Timer

Number of days, hours, minutes, and seconds since the last reset

Receive Level

Number of times the data level was too low to be detected

SpeedCop Violations

Number of times the data rate exceeded the selected rate

CDR Unlock

Number of times the data rate did not match the selected clock rate

3.6.1 Utilities Screen

Use the Utilities screen to set the time and date; change the password; set values for various
parameters, including for communications; or to run the diagnostic PING. See Figure 15 and Table 8.
To access the Utilities screen, follow this step:

1. From the Main Menu, type

4

, "Utilities," and press <Enter>. The Utilities menu appears.

UTILITIES
1) Set Date and Time
2) New Password
3) Modem/Slip/PPP Baud Rate 19200
4) Modem Initialization String AT
5) Reset Configuration To Default
6) PING Generation

Figure 15. Utilities Screen