CANOGA PERKINS N525 Ethernet Termination Service Unit User Manual

Page 13

Advertising
background image

N525 Ethernet Termination Service Unit

2-3

Figure 7 – Bottom of N525 showing Wall Mount Holes

c. Desktop/Shelf Placement: Place the N525 on a secure, flat surface within reach

of the power and fiber optic cables. Leave clearance on the sides (1”), front (5”)
and rear (3”) for ventilation and to facilitate Interface Module Access, Cable
Access and Power Entry.

3. Insert Interface Modules:

a. Determine which Interface Modules are for the Extension (EXT) and User (USR)

Ports.

b. Insert a module into the appropriate slot and push firmly on the center of the front

panel. If it does not seat properly, pull the module out, inspect for bent connector
pins. If there are bent pins or other obstructions, contact Canoga Technical
Support for instructions. If all appears normal, reinsert.

c. When firmly seated, hand-tighten the screw on the Module’s front panel.

4. Connect Chassis Ground: The rear of the N525 has a Grounding Lug for connecting the

N525 to Earth Ground. This is required for full electrical safety. Attach a 6 Gauge
copper cable between the Ground Lug and Earth Ground.

Wall Mounting Holes