CANOGA PERKINS N525 Ethernet Termination Service Unit User Manual
Page 48
![background image](/manuals/651380/48/background.png)
3-30
N525 Ethernet Termination Service Unit
To run the new software, swap banks, and reset the module. Follow these steps:
1. From the Main Menu, type [
7
], "Software Upgrade," and press <Enter>.
2. At the Software Upgrade Menu, type [
2
], "Swap Bank & Reset," press <Tab> to highlight
the Remote column, and press <Enter>.
3. Type [
2
], "Swap Bank & Reset," check that the Local column is highlighted, and press
<Enter>. Both modules reset and start using the new firmware.
------------------------------------SOFTWARE UPGRADE----------------------------
Time Since Last Restart 2 days 13:53:23
Local Remote Offline
Last Data
Active Firmware 96.05
Inactive Firmware 12.15
Bootcode 06.30
1) Software Reset Reset Reset
2) Swap Bank & Reset Swap Swap
3) Get New File with TFTP
Select [1-3]:
------------------------------------Messages------------------------------------
Swap