d. Minimum Punctuation Characters

Minimum number of Punctuation characters required in a valid password. 0 – 15
Characters, 0 disables restriction.

e. Maximum Consecutive Character Types

Maximum number consecutive characters of the same character type (Alpha,
Numeric, Punctuation) allowed in a valid password. 0 – 15 Characters, 0
disables restriction.

f. Maximum Same Character

Maximum number of times a character can be used in a valid password. 0 – 15
Characters, 0 disables restriction.

g. Allow Username in Password

Enable or disable using the username as or within the password

h. Password Expiration Time

Sets in days, 1 through 365, that the passwords must be reset. , 0 disables
Password Expiration.

i. Password Reuse Count

Set if the current password can be reused or must be changed to something
different. A setting of 0 allows reuse, 1 requires a different password.

Lockout/Logout Configuration

a. Lockout After Failed Attempts

Sets the number of failed attempts log-in before the user is locked out. 0 – 10
attempts, 0 disables the Lockout function.

b. Lockout Type

Hard

requires another user with Supervisor access to unlock the account in the

User Accounts Menu. Timed requires the User wait (Lockout time) before
attempting another log-in attempt.
Lockout Time
Lockout time period, 0 to 30 minutes.

c. Display Lockout Message

Enables or disables user screen display of a Lockout Message

d. Lockout Message

Sets the Lockout Message to be displayed when the user is Locked Out, up to 30
characters in length

e. Lockout Craft Port

Enables or disable management access from the RS-232 Serial Port to prevent
unauthorized access The craft port can be re-enabled from a Telnet session or a
SNMP command

f. Inactivity Logout Time

Sets the time, 0 to 30 minutes, when a user session is automatically logged out
and disconnected due to inactivity. 0 disables the function.

4. To return to the Main Menu, press <Esc>.